BlindMaster24 80eb5712b6 fix(amneziawg): re-run the forward guard once a new row has its own ports
normalizeAmneziaWGSettings validates every client's ForwardedPorts before the row
is saved, and loadPortConflictContext then reads the database -- so the new
AmneziaWG row is never a candidate for itself. A client could forward exactly the
relay port the row's own id derives, or its own WireGuard listen port, and the
create was accepted: at runtime the panel's wildcard forward listener and Xray's
127.0.0.1 relay race for the same port, and a lost relay bind makes Xray refuse
the whole generated config (#6544 review, pre-existing).

The post-Save block is the only place the id is known, so it re-runs the guard
there. Both callers now share amneziaWGForwardedPortsConflict, so the collision
message lives in one place instead of two.

TestAddInbound_AmneziawgRefusesAClientForwardingItsOwnRelayPort fails without
this -- watched red first -- and passes with it.