mirror of
https://github.com/MHSanaei/3x-ui.git
synced 2026-07-06 21:04:20 +00:00
837cf5f24e
A counter pushed past int64 (multi-node setups hit this via historic delta-compounding bugs) makes SQLite silently promote the INTEGER cell to REAL. From then on the column no longer scans into the Go int64 field and every reader of client_traffics fails at once: the inbounds page, xray restarts, and node traffic sync all return "converting driver.Value type float64 to int64". Two-part fix: every unbounded "up = up + ?" add (local traffic, node delta merge, inbound counters, plus the Go-side outbound accumulation) now saturates at TrafficMax, a cap safely below math.MaxInt64 so one more delta cannot overflow; and a startup repair casts REAL-promoted cells back to INTEGER and clamps all traffic counters into [0, TrafficMax] across client_traffics, inbounds, outbound_traffics and node_client_traffics, restoring access to already-corrupted panels without manual sqlite surgery. Closes #5762